News & Trends
How One Industrial Facility Reduced Power Supply Failures by 60% Using WAGO DIN Rail Power Supplies
A pharmaceutical manufacturing facility in Pune was facing recurring power supply failures across its industrial control panels. These failures frequently interrupted batch processing, increased emergency maintenance requirements, and created additional costs due to batch documentation and revalidation procedures. The facility needed a reliable solution that could improve power supply performance and reduce unexpected downtime.
After reviewing its electrical infrastructure, the engineering team identified that outdated power supply specifications were contributing to the problem. The facility decided to evaluate its existing 24VDC DIN rail power supplies and explore more suitable alternatives, including solutions from WAGO.
The Real Challenge
The facility operated 24 control panels, with each panel depending on a stable DC power supply for its control systems and connected equipment. However, the original power supply specifications had not been reviewed for approximately seven years.
Over time, equipment upgrades and changes in electrical loads had increased power requirements without corresponding updates to the power supply ratings. As a result, several panels were operating their power supplies at 85 to 90 percent of their rated capacity continuously.
Operating at such high utilization levels can increase internal temperatures, accelerate component aging, and affect long-term reliability. The facility was experiencing approximately one power supply failure every six weeks, creating operational disruptions and putting additional pressure on its maintenance team.
How the Facility Addressed the Problem
The engineering team conducted a detailed assessment of all 24 control panels. Instead of relying only on the original electrical specifications, technicians recorded actual current consumption across the panels over a two-week monitoring period.
The findings helped identify undersized power supplies and panels experiencing higher-than-expected electrical loads.
Based on the assessment, the facility replaced the existing units with appropriately rated DIN rail power supplies. The new specifications were selected to ensure that each power supply operated at approximately 60 to 70 percent of its rated capacity under normal operating conditions.
The team also considered additional technical requirements, including active power factor correction and conformal coating for applications exposed to higher humidity levels.
WAGO DIN rail power supplies were considered as part of the upgraded power distribution solution, helping the facility focus on reliable operation, appropriate capacity, and improved electrical performance.
The Results and Key Takeaways
Following the upgrade, the facility reported zero power supply failures over the next 18 months. This represented a significant improvement compared with its previous maintenance experience and helped eliminate unexpected interruptions associated with power supply failures.
The case highlights why selecting the correct DIN rail power supplies is important for industrial operations. Regular specification reviews, accurate load measurements, sufficient capacity margins, and suitable environmental protection can contribute to better equipment reliability.
For industrial facilities, reviewing power supply requirements every three to five years or after major equipment upgrades can help identify potential problems before they cause operational disruptions. Proper sizing and selecting suitable power supply features can support more stable control panel performance and reduce unplanned maintenance.
0 Comments
No comments yet. Be the first to respond.
Log in to comment